Maple-systems MAP450D Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačové příslušenství Maple-systems MAP450D. Maple Systems MAP450D User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 46
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Operation Manual
808 134th Street SW, Suite 120
Everett, WA 98204, USA
Phone: (425) 745-3229
Fax: (425) 745-3429
E-mail: maple@maple-systems.com
Web: www.maple-systems.com
1010-0101, Rev. 00
E
N
T
E
R
DELETE
CLEAR
SHIFT
#
:
,
?
%
$
=
*
/
+
-
.
SPACE
5
64
8
0
97
2 31
H I J K M
G
L
O T US
Q
R
Y ZX
A B C D FE
P
N
V W
Zobrazit stránku 0
1 2 3 4 5 6 ... 45 46

Shrnutí obsahu

Strany 1 - Operation Manual

Operation Manual808 134th Street SW, Suite 120Everett, WA 98204, USAPhone: (425) 745-3229Fax: (425) 745-3429E-mail: [email protected]: www.ma

Strany 2 - Table of Contents

Software HandshakingSoftware handshaking, which uses the XON/XOff format, is available only in Interactivemode. The following rules apply:1. When the

Strany 3 - About Your Documentation

Operating Mode SettingThis parameter determines whether the OIT operates in Interactive, Block, or Networkmode. Refer to Chapter 2: Operating Modes fo

Strany 4 - Operational Overview

Append Linefeed SettingThis parameter determines whether a linefeed LF control character (0x0A) will beappended to any carriage returnCR control chara

Strany 5 - OIT Configuration

Block Echo SettingThis parameter determines whether block echo is used when the OIT is operating inBlock or Network mode. If enabled, each character s

Strany 6 - 5 MAP450D Operation Manual

Delayed Linefeed SettingThis parameter determines whether the OIT executes an LF control code (hexadecimal0A) immediately or when the next character i

Strany 7 - Operating Parameters

Network Address SettingThis parameter determines the network address used by the host controller tocommunicate with this OIT when in Network mode. Opt

Strany 8 - Data Bits Setting

Cursor Type SettingThis parameter determines the type of cursor used in the OIT’s display. Options are NoCursor and Underline.Factory Default: Underli

Strany 9 - Handshaking Setting

Local Keyboard SettingThis parameter determines whether the OIT’s keyboard is enabled.Factory Default: EnabledTo modify this parameter usingSTEPware-1

Strany 10 - 1010-0101, Rev. 00

Local Setup SettingThis parameter determines whether the OIT allows you to access Configuration mode. Ifthis parameter is disabled, you will not be ab

Strany 11 - Line Terminator Setting

CHAPTER 2Operating ModesYour OIT can be programmed to operate in one of three operating modes: Interactive,Block, or Network. These modes affect how t

Strany 12 - Local Echo Setting

Table of ContentsINTRODUCTION: Welcome ...2About Your Documentation ...2Conventions ...

Strany 13 - Turn-Around Delay Setting

OIT Key Data Sent to Host Local Echo Mode OperationDelete DELDeletes the character to the left of the cursor andmoves the cursor one position left. If

Strany 14 - Use 3-Wire RS-485 Setting

OIT Key OperationShift + (8 $) Sends dollar sign ($) to the Keyboard Input Buffer and the OIT’s display.Shift + (9 +) Sends plus sign (+) to the Keybo

Strany 15 - Tab Width Setting

When using Network mode, always follow these rules:1. Every OIT on the network must be assigned a unique network address.2. Every OIT on the network m

Strany 16 - Wrap Around Setting

Sample Network SessionBelow is a sample session showing a host controller communicating with three OITs on amultidrop network. The OITs have network a

Strany 17 - Key Click Setting

This page intentionally left blank.23 MAP450D Operation Manual1010-0101, Rev. 00

Strany 18 - Passwords Setting

CHAPTER 3Using the OIT’s DisplayThe OIT displays data input from the OIT’s keypad, data sent from the host controller,and data stored in predefined me

Strany 19 - Operating Modes

When the cursor reaches the end of the current display line:•in Interactive mode, additional characters overwrite the character in the last column,unl

Strany 20 - Block Mode

In addition to the standard printable ASCII characters, the host controller can also displaycharacters from the OIT’s extended character set. Refer to

Strany 21 - Network Mode

Displaying Text from Predefined MessagesIn some applications, the OIT may be required to display many messages to the OIToperator concerning the state

Strany 22 - Network Addressing

APPENDIX AControl CommandsControl commands are multiple ASCII characters, starting with the command initiator (ESCcontrol character) and ending with t

Strany 23 - Sample Network Session

INTRODUCTIONWelcomeThank you for purchasing a Maple Systems MAP450D. You have selected a rugged,reliable and powerful operator interface terminal (OIT

Strany 24 - 23 MAP450D Operation Manual

ControlCharacterDecimalNotationHexadecimalNotationBASICCommandTerminal KeyboardKeypressesESC 27 1B CHR$(27) CTRL [STX 2 02 CHR$(2) CTRL BCR 13 0D CHR$

Strany 25 - Using the OIT’s Display

Display and Cursor Format Control CommandESC d00cursor delayedLF terminatorcursor: 0 = no change, 1 = disable cursor, 2 = enable cursordelayed LF: 0 =

Strany 26

Set Communications Parameters CommandESC B baud parity databits terminatorbaud: 0 = no change, 1 = 300 baud, 2 = 600 baud, 3 = 1200 baud,4 = 2400 baud

Strany 27 - Using a Display Variable

Sound Bell CommandESC g seconds terminatorseconds: 0 = turn bell off, 1 to 60 = sound bell for n secondsResponse: noneDescription: Allows the host con

Strany 28 - 27 MAP450D Operation Manual

Request Keyboard Buffer Status CommandESC ? terminatorResponse: status terminatorstatus: 0 = buffer empty1 = keyboard input in progress (Block and Net

Strany 29 - Control Commands

Write Display Variable CommandESC v text terminatortext: ASCII characters to be written to the display variableResponse: noneDescription: Allows the h

Strany 30 - Set LCD Viewing Angle Command

This page intentionally left blank.35 MAP450D Operation Manual1010-0101, Rev. 00

Strany 31 - Set Turn-Around Delay Command

APPENDIX BControl CodesControl codes are non-printable ASCII control characters sent from the host controller tothe OIT which cause the OIT to perform

Strany 32 - Echo Back Text Command

This page intentionally left blank.37 MAP450D Operation Manual1010-0101, Rev. 00

Strany 33 - Poll OIT Buffer Command

APPENDIX CExtended Character SetThe following table lists the extended character set for the MAP450D.If the OIT receives one of the listed ASCII Codes

Strany 34 - Display Control Commands

Operational OverviewThe MAP450D Operator Interface Terminal (OIT) provides the human-machine interfacebetween an operator and an ASCII compatible comp

Strany 35 - Read Cursor Position Command

This page intentionally left blank.39 MAP450D Operation Manual1010-0101, Rev. 00

Strany 36 - 35 MAP450D Operation Manual

APPENDIX DASCII TableHEX ASCIICODE CHAR KEY DESCRIPTION00 NUL Null01 SOH Start of header02 STX Start of text03 ETX End of text07 BEL Bell output08 BS

Strany 37 - Control Codes

HEX ASCIICODE CHAR KEY DESCRIPTION44 D D Letter D45 E E Letter E46 F F Letter F47 G G Letter G48 H H Letter H49 I I Letter I4A J J Letter J4B K K Lett

Strany 38 - 37 MAP450D Operation Manual

APPENDIX ETroubleshootingWhen Power is Applied the OIT’s Display is Blank and the OITBeepsThis indicates that the OIT does not contain a complete proj

Strany 39 - Extended Character Set

The OIT’s Keypad is Not Responding As ExpectedMany operating parameters affect the operation of the OIT’s keypad. Therefore, if a keyis not operating

Strany 40 - 39 MAP450D Operation Manual

Index 11010-0101, Rev 00Index!3-Wire RS-485 setting 13AASCII Table 40BBaud RateBaud Rate setting 6Set Communications Parameters control command 31Bloc

Strany 41 - ASCII Table

2 MAP450D Operation Manual1010-0101, Rev 00EEcho Back Text control command 31Extended Character Set 24, 38Inserting into a Predefined Message 24HHands

Strany 42 - CODE CHAR KEY DESCRIPTION

CHAPTER 1OIT ConfigurationThe OIT has many operating parameters that control how it communicates to the hostcontroller. These operating parameters can

Strany 43 - Troubleshooting

3. At Password?, type the setup password and then press the OIT’s ENTER key. If there isno setup password, just press the OIT’s ENTER key. Down/Upload

Strany 44 - 43 MAP450D Operation Manual

Operating ParametersThe OIT has many operating parameters which determine how it communicates to thehost controller. These operating parameters can be

Strany 45 - 1010-0101, Rev 00

Parity SettingThis parameter determines the parity that the OIT uses to communicate to the hostcontroller. Options are Even, Odd, None, Mark, Space. W

Strany 46 - 2 MAP450D Operation Manual

Stop Bits SettingThis parameter determines the number of stop bits that the OIT uses to communicate tothe host controller. Options are 1 Bit or 2 Bits